<ALARM SETUP>
FastCam III has four alarm inputs, which can be programmed as N.C. or N.O. When
an alarm signal is received, it can triggers the user-defined action ALARM ACT
(revise, pre001~128) and ALARM OUTPUT can be define as DISABLE,
CONTINUE, 60 SECONDs.
Disable
When alarms triggers, no action will be responds.
Continue
When alarms triggers, FastCam III will keep sending out a signal, till operator turn
off
60 seconds
When alarms triggers, FastCam III will send out signal for 60 seconds.
2. <PASSWORD SETUP>
PASSWORD SETUP
FastCam III features password protection to prevent unauthorized changes to the dome
settings. An operator can open the System Information and Display Setup Screens, but cannot
PASSWORD SETUP
→PASSWORD: DISABLE/ENABLE
PASSWORD: ------------
CONFIRM :--------------
BACK
EXIT
<CALL1 . . . 9>EQ<1 . . . 9>
OTHERS
ALARM SETUP
PASSWORD SETUP
TV SYSTEM: NTSC
TEMPERATURE: AUTO
CAMERA BRAND: AUTO
BACK
EXIT